Frequency intercommunity | |
Frequency range | DC-0.5Hz~3MHz,,,,,,,,With five digits LED display,,,,,,,,Maximum resolution 0.001Hz,,,,,,,,it is divided into six file, and use the rotary switch to selection |
Input waveform | Totally have six waveform: Oblique wave, triangle wave, sine wave, square wave, is pulse wave and negative pulse. knobbing switch can directly choose output |
stability | 0.1%-In the boot after 15 minutes. 0.2%-In the boot after 24 hours |
Dc offset | Continuous variable、 switch isolation dc; Maximum range + - 10V(unloaded),,,,,,,, + - 5V(50Ωload) |
Oblique wave | |
Frequency range | 0.5Hz ~ 2.5MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
Symmetry proportion | Compare with 15%( Decline range) ,the 85%( Up band)<5%(1Hz ~ 100kHz) |
Rising wave linear | <1%(1Hz ~ 100kHz) |
Triangular wave | |
Frequency range | 0.5Hz ~ 3MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
Symmetry proportion | Compare with 15%( Decline range) ,the 50%( Up band)<5%(1Hz ~ 100kHz) |
Linear | <1%(1Hz ~ 100kHz) |
sine wave. | |
Frequency range | 0.5Hz ~ 3MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
symmetry | Compare with 50%( Decline range) ,the 50%( Up band)<5%(1Hz ~ 100kHz) |
distortion | <1% to 100kHz |
Harmonic proportion | <30dB to 3MHz |
Frequency response | <0.1dB to 100MHz <1dB to 3MHz |
Square wave | |
Frequency range | 0.5Hz ~ 3MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
symmetry | Compare with 50%( Negative half cycle) ,the 50%( The positive half cycle)error<1% to 100kHz |
Rise time | <60nS |
Is pulse wave | |
Frequency range | 0.5Hz ~ 2.5MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
Is pulse width | 0.4sec ~ 100nS(Continuous adjustable) |
symmetry | Compare with 85%( Negative baseline),the 15%( Is pulse wave)error 5% to 100kHz |
Rise time | <60nS |
Negative pulse wave | |
Frequency range | 0.5Hz ~ 2.5MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
Negative pulse width | 0.4sec~100nS |
Symmetry | Compare with 15%( Negative pulse wave) ,the 85%( Is base)error<5% to100kHz |
fall time | <60nS |
Main output end | |
Output impedance | 50Ω,,,,,,,,error<2% |
Max output | 20Vp-p(Unloaded ),,,,,,,,0.05Vp-p(50Ωload) error: + - 0.5V |
Min output | 0.1Vp-p(unloaded),,,,,,,,0.05Vp-p(50Ωload) |
Attenuator | -20dB An Attenuation switch ; Attenuation error:<2% |
Synchronous output end | |
Output level | TTL level,,,,,,,,>3Vp-p Fixed amplitude |
Fan three-dimensional | >20 |
Rise time | <30nS |
VCF input | |
Input level | 0~10V Voltage input |
Maximum frequency change guy | 1 : 1 ~ 1 : 1000 |
Input frequency | DC - 1kHz |
Scanning synchronous output end | |
Output resistance | 1kΩ,,,,,,,,error<2% |
Output waveform | LINEAR or LOG scan Oblique wave |
Output amplitude | 10Vp-p(unloaded),,,,,,,,5Vp-p(51kΩload) |
output frequency | Continuous variable,,,,,,,,0.2Hz ~ 100Hz |
Scanning generator | |
scan mode | LINEAR/ LOG scan ,,,,,,,,With switch |
scan rate | 5sec ~ 10mS,,,,,,,,Continuous variable |
run length | 1 : 1 ~ 1 : 100(with frequency control to use) |
general characteristic | |
Operating environment | temperature:0 ~ 40 ; humidity 0 ~ 90% |
Operating Voltage | AC 115V(+-10%) 50/60Hz , FUSE 600mA。。。。。。。 |
Consumed power | Max 25VA(W) |
Scattered heat | Dedicated heat removal fan DC 12V/100mA |
Security certification | CE,GS,UL,CUL (Inspection qualified) |
size | 275mm(width) x 90mm(Height) x 300mm( depth) |
weight | 2.5Kg(Net) |
Attached | specification,,,,,,,,Power cord |
Negative pulse wave | |
Frequency range | 0.5Hz ~ 2.5MHz,,,,,,,,With five digits LED display |
Maximum resolution | 0.001Hz |
Negative pulse width | 0.4sec~100nS |
Symmetry | Compare with 15%( Negative pulse wave) ,the 85%( Is base)error<5% to100kHz |
fall time | <60nS |
Main output end | |
Output impedance | 50Ω,,,,,,,,error<2% |
Max output | 20Vp-p(Unloaded ),,,,,,,,0.05Vp-p(50Ωload) error: + - 0.5V |
Min output | 0.1Vp-p(unloaded),,,,,,,,0.05Vp-p(50Ωload) |
attenuator | -20dB An Attenuation switch ; Attenuation error:<2% |
Synchronous output end | |
Output level | TTL level,,,,,,,,>3Vp-p Fixed amplitude |
Fan three-dimensional | >20 |
Rise time | <30nS |
VCF input | |
Input level | 0~10V Voltage input |
Maximum frequency change guy | 1 : 1 ~ 1 : 1000 |
Input frequency | DC ~ 1kHz |
Scanning synchronous output end | |
Output resistance | 1kΩ,,,,,,,,error<2% |
Output waveform | LINEAR or LOG scan Oblique wave |
Output amplitude | 10Vp-p(unloaded),,,,,,,,5Vp-p(51kΩload) |
output frequency | Continuous variable,,,,,,,,0.2Hz ~ 100Hz |
Scanning generator | |
scan mode | LINEAR/ LOG scan ,,,,,,,,With switch |
scan rate | 5sec ~ 10mS,,,,,,,,Continuous variable |
run length | 1 : 1 ~ 1 : 100(with frequency control to use) |
general characteristic | |
Operating environment | temperature:0 ~ 40 ; humidity 0 ~ 90% |
Operating Voltage | AC 115V(+-10%) 50/60Hz , FUSE 600mA。。。。。。。 |
Consumed power | Max 25VA(W) |
Scattered heat | Dedicated heat removal fan DC 12V/100mA |
Security certification | CE,GS,UL,CUL (Inspection qualified) |
size | 275mm(width) x 90mm(Height) x 300mm( depth) |
weight | 2.5Kg(Net) |
Attached | specification,,,,,,,,Power cord |